Shenzhen

Welcome to our website

High-speed Multi-axis Laser Diameter Gauges

It utilises a pulsed laser light source for high-speed exposure, with exposure times as

low as 0.5 μs, enabling clear imaging of vibrating wire materials and yielding

accurate measurement results.

Repeatability    ±0.2μm

 

Category:

Description

High-speed Laser Micrometers

The F-K series is based on the principle of laser diffraction (Fresnel diffraction). With its simple design, it enables long-term, stable

and accurate measurements. With an exposure speed of as fast as 0.5 μs, it can accurately measure even vibrating wire.

With a sampling rate of 10 kHz, the system can measure the surface irregularities of wire.

The design, which contains no internal motors or optical lenses, eliminates the need for cumbersome calibration and maintenance of related

components during use, significantly reducing operational complexity and enhancing ease of use.

The product offers both dual-axis and four-axis measurement solutions, covering measurement ranges of 0.2–10 mm and 0.5–30 mm,

respectively, and is suitable for measuring wires and cables, steel wires, enamelled wires, medical tubing, 3D printing filaments and other similar materials.

The four-axis measurement solution has a smaller measurement blind spot and provides more comprehensive data acquisition, better reflecting the true condition

of the wire, making it particularly well-suited for production environments where high-quality wire is required.

High-speed Laser Micrometers
ModelF2010-SF2030-SF2010-KF2030-KF4010-K
Axis2-axis2-axis2-axis2-axis4-axis
Measurement datadiameter & ovalitydiameter & ovalitydiameter 、 ovality 、
lump & necks
diameter 、ovality 、
lump & necks
diameter、ovality 、
lump & necks
Frequency1000Hz1000Hz10KHz5 KHz10KHz
Measurement range0.2~10mm0.5~30mm0.2~10mm0.5~30mm0.3~10mm
Repeatability±0.1μm( 1 )±0.2μm( 2 )±0.1μm( 1 )±0.2μm( 2 )±0.2μm( 1 )
Accuracy± (0.0005+0.01% * D)mm( 3 )± (0.001+0.01% * D)mm( 4 )± (0.0005+0.01% * D)mm( 3 )± (0.001+0.01% * D)mm( 4 ) Diameter accuracy(mm)
±(0.001+0.01% * D)( 3 )
Ovality accuracy(mm)
< 0.5 mm:±0.004
≥0.5 mm: ±2 * (0.001+0.01% * D)
Min defect heightN/AN/A0.01mm0.01mm0.01mm
Min defect length( 5)N/AN/A0.2 mm@120m/ min
0.5 mm@300m/ min
0.2 mm@60m/ min
0.5 mm@150m/ min
0.2 mm@120m/ min
0.5 mm@300m/ min
Size155x140x58mm280x245x58mm155x140x58mm280x245x58mm275x242x60mm
Power supply24VDC ±5% , Max .42W24VDC ±5% , Max .46W24VDC ±5% , Max .42W24VDC ±5% , Max .46W24VDC ±5% , Max .46W
Working temperature\ \ \ \ 5~50 ℃
Display\ \ \ \ LED display
Commuincation port Standard:RS485 MODBUS RTU
Option:PROFI BUS 、PROFINET 、 EtherNet/IP 、EtherCAT( 6 )
Electrical port Standard: digital output(relay) ,digital input ,encoder pulse input port
Option: PI feedback control( 6 )
Data colletion & analysis\ \ \ \ Options:TDC 3000, DMS1000, C3, DS14ZT
Out-of-tolerance alarm\ \ \ \ Available
Transparent mode\ \ \ \ Available
Note: (1)Set average time to 0 . 1s and measure the ±2σvalue of the 1mm round rod at the measurement area center;
(2)Set average time to 0 . 1s and measure the ±2σvalue of the φ10mm round rod at the measurement area center;
(3)Move φ1mm round rod in the measurement area and conduct measurement error;
\ \ \ \ \ \ \ (4)Move 10mm round rod in the measurement area and conduct measurement error;
\ \ \ \ \ \ \ (5)set defect measurement average time as 0ms, the minimum defect length which cannot be missed at the measurable area;
\ \ \ \ \ \ \ (6)Industrial communication module and PI feedback control module is installed before ex-factory,so notify the demand before placing an order.

 